Case study · FEA driven redesign

Spoon HitchStructural Redesign

A focused geometry redesign reduced the reported peak stress under the OEM’s specified static load case while retaining the hitch interfaces and material specification.

Sector
Trailer components
Service
Structural and stress FEA
Focus
Stress concentration

Comparison basis

Loading
The same specified static load case before and after redesign.
Material
The original material grade and heat treatment specification retained.
Interfaces
Mounting, hitch engagement and surrounding clearance treated as fixed constraints.
01 Engineering challenge

Resolve the stress concentration

The initial spoon hitch analysis placed the local peak close to the material yield reference used for the assessment. The OEM had already identified the problem; Fabrixon’s brief was to resolve it within the existing interface envelope.

Reanalysis in ANSYS Mechanical focused on a sharp internal transition where the load passed through a locally restricted section. Progressive mesh refinement was used to check the reported peak before the geometry was changed.

Root cause
The concentration occurred at an abrupt change in the load carrying geometry.
Constraint
The engagement geometry, mounting pattern and surrounding envelope could not be treated as free redesign space.
Method
Local geometry iteration with repeat analysis, rather than a changed load case or a material upgrade.
02 Geometry iteration

Change the load path, not the brief

The redesign combined smoother transitions and local support while retaining the OEM’s fixed interfaces. Each iteration was reanalysed with the same mesh refinement discipline used for the baseline.

  1. 01

    Smooth the transition

    Replace the sharp internal change with fillet geometry that distributes load through the transition.

  2. 02

    Support the peak region

    Add supporting section where the analysis showed the demand, rather than increasing material uniformly across the component.

  3. 03

    Recheck the envelope

    Balance the stress improvement with clearances, mounting constraints and manufacturability in each iteration.

03 Static analysis result

Lower stress under the same load

Repeat analysis confirmed a reduction in peak von Mises stress from the initial to the redesigned geometry. The improvement was achieved through geometry while the stated material and load case remained unchanged.

Reported comparison
MetricInitial geometryRedesigned geometry
Peak von Mises stress648 MPa338 MPa
Peak stress reductionBaseline48% lower

The stress reduction is rounded to the nearest whole percentage. This comparison is a static structural result, not a fatigue life prediction.

04 Engineering outcome

Evidence for the redesigned release

The engineering engagement combined the initial analysis, geometric redesign and repeat assessment in one report. The revised component was released for fabrication without changing the mounting or hitch engagement geometry.

Design change
Smoother transitions and targeted local section support addressed the source of the concentration.
Analysis scope
Static linear FEA under the specified load case. Fatigue under service load history remains a separate assessment.
Release evidence
The engineering report documented the comparison, modelling basis and scope for the OEM’s design release.